| Parameter | Value | Unit |
|---|---|---|
| Series type | BY5015 | |
| Dimensions | 50x50x15mm | mm |
| Frame Type | Black PBT (UL94V-0) | |
| Impeller | Black PBT (UL94V-0) | |
| Bearing | Two Ball & (Sleeve or Hydraulic Bearing) | |
| Operation Temperature | -10℃~70℃ (Ordinary humidity) | |
| Storage Temperature | -40℃~80℃ (Ordinary humidity) | |
| Lead wire | (+) Red,(-) Black,(FG/RDYello,(PWM) Blue | |
| Safety | CE approved, RoHS | |
| Ingress of Protection | IP42 or IP55 | |
| Unit Weight | :30g |
| Model No. | Grade | Op. Voltage (VDC) |
Current (A) |
Power (W) |
Speed (RPM) |
Air Flow (CFM) |
Air Flow (m³/min) |
Static Pressure (mmH₂O) |
Static Pressure (Pa) |
Noise (dBA) |
|---|---|---|---|---|---|---|---|---|---|---|
| HR5015HD5(-SF) | HD | 4~6 | 0.3 | 1.5 | 6,000 | 14.05 | 0.4 | 4.27 | 41.87 | 38.9 |
| HR5015MD5(-SF) | MD | 4~6 | 0.2 | 1 | 5,000 | 11.4 | 0.32 | 3.12 | 30.6 | 34.9 |
| HR5015LD5(-SF) | LD | 4~6 | 0.16 | 0.8 | 4,000 | 8.92 | 0.25 | 2.02 | 19.81 | 30 |
HD = High Speed | MD = Medium Speed | LD = Low Speed
| Motors Protection | Signal Output | Speed Control | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RP | AS | CS | CL | OV | SS | FG | RD/RD/b | LD | PPWM | VPWM | TC | RC |
| ● | ● | ● | ○ | ○ | ● | ● | ● | ○ | ● | ○ | ○ | ○ |
● Supported ○ Not available
Submit your requirements for HR5015(-SF) 5V. Our team responds within 24 hours with pricing and lead time.