Air delivery through a defined air path
Consider this blower when your design needs air routed through an outlet, duct or other defined air path. Share the required flow and system resistance so the operating point can be checked.
Match the blower to your air path, pressure requirement and power supply. Confirm the exact configuration and its operating point for your equipment.
| Parameter | Value | Unit |
|---|---|---|
| Source page | 29 | |
| Dimensions | 90x80mm | mm |
| Type | A Type | |
| Rated voltage | 24 | V |
| Operating voltage | 18.5~26.5 | V |
| Rated current | 15.3 | A |
| Rated input power | 367.2 | W |
| Speed | 48000 | RPM |
| Maximum airflow | 72.4 | CFM |
| Maximum static pressure | 1842.8 | mmH2O |
| Noise | 72.55 | dBA |
| Application | Medical and home ventilator / CPAP | |
| Bearing | Ball / configurable bearing code per TKFAN catalog | |
| Frame | Plastic, UL94V-0 where specified | |
| Impeller | Plastic, UL94V-0 where specified |
Match the blower to your air path, pressure requirement and power supply. Use the checks below to shortlist the correct configuration before requesting a quote or sample.
Consider this blower when your design needs air routed through an outlet, duct or other defined air path. Share the required flow and system resistance so the operating point can be checked.
The listed dimensions are 90x80mm. Verify hole positions, clearance and airflow direction against the drawing before installation.
This page lists a 24V rated supply. Check the selected model’s operating voltage, current and power before connecting it to your system.
Compare the listed airflow with the flow required at your system’s operating pressure.
Evaluate noise in the installed equipment, including the enclosure, mounting and operating speed.
Use the Performance section to compare flow at your required pressure. Send your target operating point with your inquiry.
Maximum airflow and maximum static pressure describe different points on a P–Q curve. They are not achieved simultaneously. Select one complete model variant and evaluate it with your actual air path.
| Installation | Review the Dimensions section, then confirm your mounting interface, outlet clearance and connector pinout. |
|---|---|
| Electrical supply | This page lists a 24V rated supply. Check the selected model’s operating voltage, current and power before connecting it to your system. Include startup requirements and supply tolerances in your inquiry. |
| Operating environment | Share ambient temperature, humidity, dust or moisture exposure and duty cycle. Confirm temperature and ingress protection requirements for the exact configuration. |
| Bearing selection | Listed bearing information: Ball / configurable bearing code per TKFAN catalog. Confirm the ordered bearing option, mounting orientation and expected operating conditions. |
| Control & monitoring | Confirm the functions, signal levels, wire count and pinout of your selected version. Do not assume every connector or wiring option includes every listed function. |
| Project requirements | Tell us your cable length, connector, speed-control and protection requirements. Ask which options can be supplied for this model, and request the relevant compliance documents for the ordered configuration. |
| Technical documents | Ask for the datasheet for the exact model and configuration in your inquiry. |
Compare the listed airflow with the flow required at your system’s operating pressure. Evaluate noise in the installed equipment, including the enclosure, mounting and operating speed. Share your thermal or airflow target, installation space and noise limit if you need help shortlisting a version.
Installed airflow depends on system resistance and the selected operating point. Use the Performance section to compare flow at your required pressure. Send your target operating point with your inquiry. Test the selected version with the actual enclosure, grille, filter or duct.
Include your connector specification, cable length, pinout and control requirements in the inquiry. We will review which options are available for HR9080H24B and confirm the configuration before quotation.
Request the reliability information, lifetime test conditions and compliance documents applicable to the exact model and configuration. Share operating temperature, duty cycle and your market requirements so the information can be reviewed for your project.
Ask for sample and production quotations with your quantity, configuration and destination. Confirm MOQ, availability, production lead time and warranty terms in the quotation for this order.
Send the information you already have. If your specification is still developing, describe the equipment and the problem you need to solve.
Ask for a model recommendation, configuration review, technical documents and a quotation covering price and delivery.
Submit your requirements for HR9080H24B. Include your selected variant, quantity and project requirements to request pricing, configuration guidance and delivery details.